Citations checked against 42 CFR Part 493 on 16 November 2026Independent publisher. Not affiliated with CMS, CDC or any accreditation organization.
CLIA Templates

Home / Point-of-care testing / Flu and COVID-19 antigen

Rapid flu and COVID-19 antigen tests: CLIA requirements and quality control

Short answer

Rapid flu and COVID-19 antigen tests are waived for the swab types their labeling names, so a Certificate of Waiver covers them when you follow the package insert, including its controls. A negative result doesn't rule out infection in a patient with symptoms.

Rapid antigen tests for influenza and COVID-19, alone or in combination, are waived for the specimens their labeling names. Their limits matter as much as their controls: CDC rates rapid influenza tests as highly specific but only low to moderately sensitive.

Reviewed 16 Nov 2026 against the sources linked below. General information, not regulatory or legal advice. Your package insert controls.

What CLIA asks of every waived test

A Certificate of Waiver site has one central duty for every test: follow the manufacturer's instructions, including controls, storage, specimen and timing (42 CFR 493.15(e)(1)). Confirm in the FDA CLIA database that your exact device is waived for the specimen you collect, and keep the current package insert with your procedure. CDC notes that most problems found at waived sites come from not following those instructions.

Quality control

  • Check that the built-in control appears on every test. If it doesn't, the result is invalid.
  • Run the external controls at the points the insert names, commonly each new lot or shipment and each new tester.
  • For a combination test, confirm in the FDA database that every analyte you report is waived for the swab you collect.

What the results can and can't tell you

  • CDC: rapid influenza tests are 50% to 70% sensitive compared with RT-PCR, or 76% to 80% with a digital analyzer reader, and at least 98% specific.
  • CDC: a negative result doesn't exclude influenza in a patient with symptoms, and antivirals shouldn't be withheld on a negative test alone.
  • CDC: false positives are more likely when influenza is uncommon, such as early and late in the season; false negatives are more likely when it is widespread.
  • CDC: collect specimens early, ideally within 3 to 4 days of onset, when the virus is shed most.
  • COVID-19 antigen tests have similar limits. Follow the insert on when a negative should be confirmed with a molecular test.

Mistakes to avoid

  • Using a nasopharyngeal swab when the kit is labeled for anterior nasal swabs, or the reverse.
  • Reading after the result window has closed.
  • Processing several specimens at once on a crowded bench, which invites mix-ups and contamination.
  • Not checking your state's reportable disease rules for positive results.

Records to keep

For each control run: date, kit or strip lot and expiration, control lot and expiration, the result against its expected range, whether it was acceptable, what you did if not, and initials. The free waived test QC log covers this for any test. The Waived Testing Kit has a ready-made "Flu and COVID-19 antigen" log with the columns for this test, plus the procedure template, lot log and temperature log.

Keep the temperature log for where kits are stored, too: the temperature log is free.

Do we need a separate CLIA certificate for COVID-19 testing?

No. A waived COVID-19 test is covered by a Certificate of Waiver like any other waived test. Add it to your test menu record and confirm its waived status for the swab you use.

Why does a negative rapid flu test still need clinical judgment?

Because the test misses a meaningful share of infections. CDC puts rapid influenza test sensitivity at 50% to 70% without a reader, so a negative in a patient with flu symptoms during flu season doesn't rule it out.

Sources

Summaries on this page are ours and are written for convenience. The regulation and the agency documents control.

Other point-of-care tests